article · Energy Reports
In power systems, the distribution network is crucial as it serves as the final stage in delivering energy from generation plants to end users. However, reactive power demand from consumers can create challenges such as low power factor, voltage drops, and increased power losses depending on the distribution system used. This study aims to enhance the performance of radial distribution networks (RDNs) by optimizing capacitor placement and sizing based on the Crow Search Algorithm (CSA). Additionally, the study addresses the Optimal Power Flow (OPF) within the network by employing the Backward/Forward Sweep (BFS) method. The study accesses CSA’s effectiveness compared to other metaheuristic optimization techniques through simulation. The simulation results showed that the Voltage Stability Index improved from 0.61 for base case to 0.68 pu with CSA, compared to 0.66 for Particle Swarm Optimization (PSO), Artificial Bee Colony (ABC), Genetic Algorithm (GA), and Teacher Learner Based Optimization (TLBO and 0.67 for Invasive Weed Optimization (IWO). CSA also achieved a 30.41 % reduction in active power losses, outperforming PSO, ABC, GA, and TLBO having 26.61 %, and IWO at 24.92 %. Additionally, application of CSA led to a 29.33 % reduction in reactive power losses, compared to 21.91 % for PSO, ABC, GA, and TLBO, 18.2 % for IWO. In the simulated IEEE 33 bus Radial Distribution Network (RDN) topology, the lowest bus voltage at bus 18 increased from 0.8820 in the base case to 0.9080 with CSA, indicating a 32.9 % improvement in voltage deviation. Furthermore, the optimization resulted in a significant reduction of 3.841 pu in capacitor cost, demonstrating CSA’s efficiency in both technical and economic aspects. CSA not only showed favorable results in minimizing power losses and improving voltage profiles but also provided substantial cost savings in capacitor implementation, making it a robust and cost-effective solution for enhancing RDN performance. • Crow Search Algorithm (CSA) optimizes capacitor placement in distribution networks. • CSA reduces active power losses by 30.41 % and reactive losses by 29.33 %. • Voltage stability index improved from 0.61 to 0.68 pu with CSA implementation. • CSA reduced capacitor costs and outperformed PSO, ABC, GA, and TLBO in simulations. • Optimal Power Flow (OPF) was enhanced using Backward/Forward Sweep (BFS) method.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.egyr.2024.10.062
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.