Transient Stability Enhancement Using Adaptive Neuro-Fuzzy-Based Unified Power Flow Controller

20244 citationsOpen accessBahir Dar University

Abstract

A power system is a complex, non-linear, and dynamic system, with operating parameters that change over time. Because of the complexity of big load lines and faults, high-voltage transmission power systems are usually vulnerable to transient instability concerns, resulting in power losses and increased voltage variation. This issue has the potential to cause catastrophic events such as cascade failure or widespread blackouts. This problem affects Ethiopia's high-voltage transmission power grid in the North-West area. Because of the increased demand for electrical energy, transmission lines' maximum carrying capacity should be enhanced to maintain a secure and uninterrupted power supply to consumers. To address the problem, an adaptive neuro-fuzzy-based unified power flow controller (ANFIS-based UPFC) is used for high-voltage transmission lines. This device was chosen as the ideal alternative due to its capacity to rapidly correct reactive power on high-voltage transmission networks. The particle swarm optimization (PSO) algorithm was used to determine the best location for the UPFC. The ANFIS controller receives voltage error and rate of change of voltage error as inputs. 70% of the retrieved data is used for ANFIS training and 30% for ANFIS testing. To show the performance of the proposed controller, several disturbances such as three-phase with ground fault and single-phase with ground fault are used. When a three-phase with ground fault occurs at the mid-point of the Beles to Bahir Dar transmission line, for example, the settling time of rotor angle deviation, rotor speed, rotor speed deviation, and output active power of synchronous generators using ANFIS-based UPFC is reduced by 70.58%, 37.75%, 37.75%, and 43.75%, respectively, compared to a system without UPFC. At peak load, PI-based UPFC and ANFIS-based UPFC reduce active power loss by 51.25% and 71.50%, respectively, compared to a system without UPFC on the Beles to Bahir Dar transmission line. In terms of percentage overshoot and settling time, ANFIS-based UPFC outperforms PI-based UPFC for transient stability enhancement.

Research topics

  • Power System Optimization and Stability
  • Power Systems Fault Detection
  • Power Quality and Harmonics

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1016/j.sciaf.2024.e02195

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.