article · Talanta Open
• First dual-mode sensing platform combining O-CDs with Ca-murexide complex for DOX detection. • Novel competitive binding mechanism enables selective differentiation of DOX from other tetracyclines. • Simple smartphone-based colorimetric platform developed for on-site DOX monitoring. • Robust analytical performance with linear range 0-35.0 μM and good precision. • Successfully validated for pharmaceutical wastewater analysis with high recovery rates. A novel and selective analytical method has been developed for doxycycline (DOX) determination, addressing the critical need for monitoring this widely used antibiotic in environmental samples. The method employs a hybrid sensing system combining orange-emitting carbon dots (O-CDs) with a calcium-murexide (Ca@Mu) complex, offering a unique dual-mode detection approach. Unlike conventional methods that rely on direct fluorescence quenching by DOX, which often suffer from poor selectivity, this system utilizes the competitive binding between DOX and murexide for Ca 2+ ions. Initially, the pink-colored Ca@Mu complex formed under alkaline conditions causes fluorescence quenching of O-CDs at 552 nm. Upon introduction of DOX, its stronger Ca 2+ -binding affinity leads to the formation of a calcium-DOX complex, liberating free Mu and triggering both colorimetric (pink to orange) and fluorometric (restoration of O-CDs emission) responses. Comprehensive characterization and mechanistic investigations employing different spectroscopic techniques confirmed the sensing mechanism. The method demonstrates excellent selectivity for DOX among other tetracyclines and potential interferents, along with impressive analytical performance including good linearity (1.0-35.0 μM), low detection limit (325 nM), and high precision. Additionally, a smartphone-based colorimetric platform was developed for convenient on-site analysis. The practical utility of this method was validated through successful determination of DOX in environmental water samples with excellent recovery rates, offering a reliable and user-friendly approach for environmental monitoring of this important antibiotic.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.talo.2025.100438
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.