MARATTO

article · QJM

Non-Invasive Electrical Cardiometry versus Echocardiography for Assessment of Patent Ductus Arteriosus Hemodynamic Response to Medical Treatment in Preterm Neonates

20241 citationAin Shams University

Abstract

Abstract Background Patent ductus arteriosus (PDA) poses a diagnostic and a therapeutic dilemma for neonatologists. Although echocardiography (Echo) has been the gold standard diagnostic tool for PDA, it requires a trained cardiologist or neonatologist to perform and it is usually not available around the clock. Echo provides also a single rather than continuous assessment of the sick neonates, whose hemodynamic status changes quickly. Electrocardiometry (EC) is a new device for continuous hemodynamic monitoring of neonates. Aim of the Work To evaluate the accuracy and precision of EC in comparison to ECHO in assessment of PDA response to treatment in preterm neonates. Patients and Methods This diagnostic accuracy study was conducted in the neonatal intensive care units (NICUs) of Children’s Hospital of Ain Shams University, Cairo, between (1/5/2021 and 31/3/2022). The study was approved by the ethical committee of Ain Shams University. Preterm neonates<35weeks gestational age admitted during the study period were eligible for enrollment. Neonates with hemodynamically non-significant PDA and those with other congenital anomalies were excluded. A baseline echo and electrical cardiometry were done at the time of enrollment and on day 5. Results Forty neonates were enrolled (27 females, 13 males). Closure rate of oral ibuprofen was 100% (39/39) while paracetamol failed to close the PDA in one patient (closure success 0%). Echo and EC didn’t agree upon the tested parameters (stroke volume (SV), cardiac index (CI), ejection fraction (EF), cardiac output (CO) but agreed in measuring heart rate (HR). In patients with inotropes, Echo detected significant changes in CO (p = 0.044) and CI (p = 0.047) but no changes in SV, EF and HR (p = 0.41, 0.506 & 0.105 respectively). In patients who needed mechanical ventilation, Echo detected significant changes in CI (p = 0.008), CO (0.006) and SV (0.042). No changes were detected in any parameter by EC in patients who needed either inotropes or mechanical ventilation (p > 0.05 in all parameters). Conclusion While EC is safe and an easy to apply device, our results show that electrocardiometry is not as accurate as the echocardiography in predicting the hemodynamic changes that might correspond to the closure of PDA in preterm neonates with hemodynamically significant PDA.

Research topics

  • Cardiovascular Conditions and Treatments
  • Congenital Heart Disease Studies
  • Cardiovascular and Diving-Related Complications

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1093/qjmed/hcae070.481

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.