MARATTO

article · Colloids and Surfaces A Physicochemical and Engineering Aspects

Non-enzymatic electrochemical sensor for uric acid based on surfactant-silica-MWCNT nanohybrids functionalized with APTES

202511 citationsOpen accessUniversity of Monastir

Abstract

The CTAB@SiO 2 @MWCNT-APTES composite was synthesized and applied as a modifier for a glassy carbon electrode (GCE) for the electrochemical the determination of uric acid (UA). APTES was successfully immobilized on multi-walled carbon nanotubes (MWCNTs) through non-covalent hydrophobic interactions and formed a nanoscale network that enhanced electron transfer and access to the detection sites. All experimental parameters were optimized, and the modified sensor exhibited a linear detection range from 5 × 10⁻⁹ to 1 × 10⁻⁸ molL⁻¹ and from 1.25 × 10⁻⁸ to 1.0 × 10 -7 molL⁻¹, a high sensitivity of 2.7 × 10⁷ µA·mol⁻¹L, and a low detection limit (LOD) of approximately 4.5×10⁻ 10 molL⁻¹. Structural characterization by FTIR, EDX and transmission electron microscopy confirmed the integrity and successful functionalization of the composite. The CTAB@SiO 2 @MWCNT-APTES-modified electrode allowed clear separation of the uric acid oxidation peak from common interfering species such as ascorbic acid and dopamine. The sensor was effectively applied to human plasma and urine samples, achieving recovery rates between 92% and 104%, confirming its potential for reliable real-sample analysis and future sensor development. • CTAB@SiO2@MWCNT-APTES composite is synthesized and characterized by FTIR and TEM • The CTAB@SiO2@MWCNT-APTES composite enhanced the electrochemical detection of uric acid. • The sensor exhibited high stability, compatibility, and selectivity in analyte detection. • A recovery of 92%-104% was achieved in plasma and urine, validating its analytical efficacy.

Research topics

  • Electrochemical sensors and biosensors
  • Analytical Chemistry and Sensors
  • Electrochemical Analysis and Applications

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1016/j.colsurfa.2025.137520

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.