Abstract

Abstract To fulfil the energy needs of the nations where it is regasified and delivered via pipelines, specialist tankers transport liquefied natural gas (LNG), a reliable and efficient energy source, across the sea. To improve efficiency and environmental acceptability, research is being done on substituting carbon dioxide for propane in the precool loop of the propane-precooled mixed refrigerant cycle. The primary goal of the research is to compare carbon dioxide and propane as refrigerants for the precooling loop of a propane-mixed refrigerant (C3-MR) cycle, which is utilised to liquefy natural gas, utilising Aspen HYSYS to design the plants. The performance of CO2 and propane were examined in this study using various process factors that were discovered through sensitivity analysis. The study determined both refrigerants’ coefficients of performance (COP), which show how well they cool while consuming less energy. In comparison to propane, which had a COP of 3.555, carbon dioxide showed a slightly higher COP of 3.728, indicating that it was more effective at transmitting heat under the given circumstances. The impact of variations in the precooling refrigerant pressure and molar flow rate on the compressor's duty for the carbon dioxide and propane precooling cycles was also examined in this study. Both refrigerants demanded more effort from the compressors as the molar flow rate was raised, but carbon dioxide fluctuated in compressor duty a little more than propane. In a similar vein, both refrigerants showed reduced compressor workload with increasing pressure, with carbon dioxide once more exhibiting somewhat greater compressor duty changes. Based on the data gathered, the study came to the conclusion that carbon dioxide, with its greater coefficient of performance, superior heat transfer efficiency, safety advantages, and less environmental impact, was the best refrigerant for the precooling loop in the C3-MR cycle.

Research topics

  • Refrigeration and Air Conditioning Technologies
  • Carbon Dioxide Capture Technologies
  • Phase Equilibria and Thermodynamics

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.2118/221605-ms

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.