MARATTO

preprint

Long term outcomes of drug-coated balloons versus drug-eluting stents in patients with small vessel coronary artery disease

20242 citationsOpen accessZagazig University

Abstract

<title>Abstract</title> Background Drug-eluting stents (DES) are a normative care of coronary stenosis. However, their efficacy was limited by stent thrombosis and in-stent restenosis especially in small vessel coronary artery disease (SvCAD). The aim of this study was to assess angiographic efficacy and clinical outcomes of drug coated balloons (DCB) as compared with DES in SvCAD setting. Methods A total of 100 SvCAD patients with percutaeous angioplasty of culprit coronary arteries &lt; 3 mm diameter and &gt; 70% stenosis were enrolled in this study. The patients were categorized into DES arm and DCB arm. One year clinical outcomes were assessed. The primary endpoint was in-lesion late lumen loss (LLL). The secondary endpoints were vessel thrombosis, major bleeding, all-cause death and major adverse cardiac events (MACEs). Results One year clinical follow-up revealed that in-lesion LLL was significantly lower in DCB arm as compared with DES arm (P = 0.004). Composite MACE was significantly higher in DES group compared to DCB group (P &lt; 0.001). Non-fatal myocardial infarction (MI), target lesion revascularization (TLR), and major bleeding in DES group were significantly higher than DCB group (P = 0.04 &amp; P &lt; 0.001 &amp; P = 0.03, respectively). However, there was a numerically; but not significantly, higher incidence of cardiac death (P = 0.65), and vessel thrombosis (P = 0.18) in DES arm compared to DES arm. Conclusion In SvCAD setting, DCB has favourable angiographic and clinical outcomes; as evidenced by lower LLL and composite MACE at one year follow up, compared to DES.

Research topics

  • Coronary Interventions and Diagnostics
  • Antiplatelet Therapy and Cardiovascular Diseases
  • Cerebrovascular and Carotid Artery Diseases

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.21203/rs.3.rs-4659117/v1

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.