Abstract

Abstract Objective To correlate µTBS of photo- and dual-polymerized luting resins with film thickness (FT), Vicker's hardness (HV) and ultimate-tensile strength (UTS). Methods Human molars (N = 30) were divided (6-groups) according to: 1: Luting resin: Dual- [Bifix QM, (BF)], or photo-polymerized [GrandioSo Heavy Flow (GHF) and VisCalor Bulk (VB)] and 2: Adhesive mode (Optibond Universal): Etch-and-rinse (ER) or self-etching (SE). CAD/CAM blocks (7x7x4mm 3 ) were air-abraded (50µm Al 2 O 3 /10s/0.2MPa) and silanated. For ER, dentin was etched (15s), rinsed (30s), and blot-dried. For both modes, adhesive was applied (20s), air-dried (5s) and photo-polymerized (10s). Sticks (1x1mm 2 ) were aged either for 24-hours or for 6-months. Sticks were pulled in tension (1mm/min). Debonded sticks were evaluated for failure mode. For FT, nine-bonded slabs/each cement were evaluated. For UTS, eight-hourglass specimens/each cement were tested. For HV, 5-discs/each cement were evaluated using Vicker’s hardness tester. Data were analysed using ANOVA/Pearson's correlation tests (α = 0.05). Results No correlation between µTBS/HV was revealed (P > 0.05). Positive correlation between µTBS/FT and µTBS/UTS ( p < 0.05) were observed. Three-Way ANOVA revealed all experimental factors had significant effect on µTBS ( p < 0.05). The VB showed significant lower µTBS (20.8 ± 9.3MPa). The ER mode showed higher µTBS (26.0 ± 10.9MPa), and 24-hours revealed the higher µTBS (27.4 ± 10.0MPa). Mixed failure was the predominate type (42.51%). The VB showed the highest FT (122.2 ± 11.9µm). The GHF revealed higher UTS and HV (112.5 ± 19.7MPa and 91.6 ± 0.4Kgf respectively). Conclusions Photo-polymerized flowable resin can substitute dual-polymerized cement for CAD/CAM composite bonding. Clinical relevance: Photo-polymerized flowable composite can replace the dual-polymerized resin cement one to bond CAD/CAM composite to dentin.

Research topics

  • Dental materials and restorations
  • Dental Research and COVID-19
  • Dental Implant Techniques and Outcomes

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.21203/rs.3.rs-3903230/v1

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.