Hybrid Radiant Disinfection: Exploring UVC and UVB Sterilization Impact on the Mechanical Characteristics of PLA Materials

Abstract

This study explores the impact of disinfection techniques on the mechanical properties of poly(lactic acid) (PLA), a crucial material in the production of medical implants, tissue engineering, orthopedic devices and drug delivery systems, owing to its biocompatibility and ease of manufacturing. The focus is on evaluating the effectiveness of ultraviolet (UV) type C (254 nm wavelength) and the combined use of type C and B (310 nm wavelength) disinfection methods. Fifteen tensile test specimens (ASTM D638) and fifteen compression test specimens (ASTM D695) were utilized to assess PLA’s mechanical properties, including yield strength, ultimate strength, and fracture strength. The investigation involved subjecting the specimens to the specified disinfection methods and evaluating these properties both before and after the disinfection process. In the tensile test, a statistically significant difference (p = 0) in yield displacement was observed among the three groups. Additionally, a notable difference (p = 0.047) in fracture displacement was identified between the untreated group and the UVC and UVB combination group. No discernible impact on yield or fracture forces was noted. In the compression test, there was a significant difference (p = 0.04) in yield displacement and a clear difference (p = 0.05) in fracture force between the untreated group and the UVC and UVB combination group. The hybrid combination of UVC and UVB disinfection techniques did not affect yield force in both tensile and compression tests. However, it demonstrated a clear impact on displacement, suggesting its potential as a promising disinfection technique in the medical field.

Research topics

  • Bone Tissue Engineering Materials
  • biodegradable polymer synthesis and properties
  • Additive Manufacturing and 3D Printing Technologies

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.3390/polym15244658

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.