article · International Journal of Electrochemical Science
The quantity of hydroxyl radicals in the Electro-Fenton process is influenced by the cathode material's H2O2 production capacity. Factors such as cathode type, current density range (50 -500 mA), and Fe2+ concentrations (0.05 - 0.2 mM) impact the efficiency. This study focuses on Grepafloxacin removal from water using Electro-Fenton, with CF outperforming CG in H2O2 generation.The optimal conditions for CF were (400 mA) and ( 0.1 mM) Fe2+. HPLC identified intermediates, and ion chromatography measured inorganic ions post-mineralization.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.ijoes.2024.100556
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.