article · Nuclear Analysis
This study investigates the critical significance of anode material selection in defining the energy spectrum and properties of X-ray photons in medical physics applications. Using the GATE platform and Monte Carlo simulations, a direct relationship between anode material atomic number and photon fluence is demonstrated. As the atomic number increases from Z=29 (Copper) to Z=74 (Tungsten), photon fluence rises by 62%, indicating a substantial impact on X-ray production. Furthermore, the X-ray spectrum is affected by this material-driven changes, revealing a noticeable shift towards higher energy values: the mean energy of the continuous spectrum rises from 46.97 keV for Copper to 49.0 keV for Tungsten. The thermal properties of the material affect the temperature increase at the focal point. Rhodium and Molybdenum have a higher temperature rise than Copper (Cu) and Tungsten (W), because Cu and W have a greater thermal diffusion compared to other materials. These findings underscore the significance of anode material choice in optimizing X-ray systems which may enhance diagnostic accuracy and efficiency in diverse applications.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.nucana.2024.100112
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.