article · IEEE Journal of Biomedical and Health Informatics
This study aims to explore the potential of Internet of Things (IoT) devices and explainable Artificial Intelligence (AI) techniques in predicting biomarker values associated with GDM when measured 13-16 weeks prior to diagnosis. We developed a system that forecasts biomarkers such as LDL, HDL, triglycerides, cholesterol, HbA1c, and results from the Oral Glucose Tolerance Test (OGTT) including fasting glucose, 1-hour, and 2-hour post-load glucose values. These biomarker values are predicted based on sensory measurements collected around week 12 of pregnancy, including continuous glucose levels, short physical movement recordings, and medical background information. To the best of our knowledge, this is the first study to forecast GDM-associated biomarker values 13 to 16 weeks prior to the GDM screening test, using continuous glucose monitoring devices, a wristband for activity detection, and medical background data. We applied machine learning models, specifically Decision Tree and Random Forest Regressors, along with Coupled-Matrix Tensor Factorisation (CMTF) and Elastic Net techniques, examining all possible combinations of these methods across different data modalities. The results demonstrated good performance for most biomarkers. On average, the models achieved Mean Squared Error (MSE) between 0.29 and 0.42 and Mean Absolute Error (MAE) between 0.23 and 0.45 for biomarkers like HDL, LDL, cholesterol, and HbA1c. For the OGTT glucose values, the average MSE ranged from 0.95 to 2.44, and the average MAE ranged from 0.72 to 0.91. Additionally, the utilisation of CMTF with Alternating Least Squares technique yielded slightly better results (0.16 MSE and 0.07 MAE on average) compared to the well-known Elastic Net feature selection technique. While our study was conducted with a limited cohort in South Africa, our findings offer promising indications regarding the potential for predicting biomarker values in pregnant women through the integration of wearable devices and medical background data in the analysis. Nevertheless, further validation on a larger, more diverse cohort is imperative to substantiate these encouraging results.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1109/jbhi.2024.3361505
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.