BACKGROUND: The scale-up of molecular assays for diagnosing emerging pathogens has increased in low-and-middle-income countries (LMICs) since the advent of COVID-19. We herein evaluated the diagnostic concordance of three different assays for SARS-CoV-2 in Cameroon. METHODS: A laboratory-based comparative study was performed on nasopharyngeal samples collected between March-2020 to March-2023 from the biobank of Chantal Biya International Reference Centre (CIRCB), Yaoundé-Cameroon. Samples were analyzed using DaAn Gene (N/ORF1ab-genes), ThermoFisher (N/ORF1ab/S-genes), and GeneXpert (N2/E-genes). Validated cycle thresholds (CT) for positivity were CT < 37 for DaAn Gene/ThermoFisher and CT < 40 for GeneXpert. Cohen's Kappa coefficient evaluated diagnostic concordance with DaAn Gene as reference. RESULTS: We analysed 249 samples (55.8% males, median-age [IQR], 36 [27-50] years including 21.3% symptomatic participants). Overall positivity rates (median [IQR]) were 55.0% (CT: 30.6 [23.1-35.5]); 53.4% (CT: 26.6 [21.2-30.9]); 22.1% (CT: 32.7 [26.9-36.1]) for GeneXpert, DaAn Gene and ThermoFisher respectively. GeneXpert showed stronger concordance with DaAn Gene (83.1%; k = 0.66, 95% CI: 0.57-0.75) than ThermoFisher (67.9%; k = 0.38, 95% CI: 0.29-0.47). At validated thresholds, GeneXpert showed higher positive agreement with DaAn Gene (85.0%, 113/133) as compared to ThermoFisher (41.3%, 55/133), while maintaining comparable negative agreement (81.0% [GeneXpert] and 98.3% [ThermoFisher]). At low CTs (< 20) however, positive agreement with DaAn Gene was high for GeneXpert (100%, 15/15) and ThermoFisher (93.3%, 14/15). CONCLUSION: GeneXpert exhibits superiority over ThermoFisher in detecting cases of COVID-19. As expected, agreement between two- and three-genes assays at CT < 20 was excellent, suggesting interoperability of these platforms during outbreaks for high viral loads cases. However, two-genes assays may be decisive to guide decision-making for effective public health response while facing intermediate to low-level viral loads in LMICs.

Research topics

  • SARS-CoV-2 detection and testing
  • COVID-19 Clinical Research Studies
  • SARS-CoV-2 and COVID-19 Research

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1002/jcla.70174

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.