Climate-responsive envelope design for educational buildings: A comparative simulation study between the UK and Egypt

Abstract

• This study compares higher-education building performance in London and Cairo. • Dynamic IES-VE modelling was verified using monitored indoor conditions. • In London, TM52 non-compliance is driven by high daily overheating severity. • In Cairo, summer conditions show extreme indoor overheating up to 38–39°C. • The findings support mixed-mode cooling and CO 2 -based ventilation control. Educational buildings increasingly face climate-driven overheating and shifting energy demand, yet transnational campuses often replicate “home-campus” typologies without climate adaptation. This study evaluates climate-responsive envelope and HVAC strategies for a higher-education studio floor in London and office spaces in Cairo using calibrated dynamic simulations supported by in-situ monitoring with 10-minutes interval temperature and CO 2 in London, short-term temperature and relative humidity in Cairo. Three scenarios were tested as follow. S01 natural ventilation; S02 mixed-mode/HVAC with existing envelope; and S03 mixed-mode/HVAC with enhanced envelope. Performance was assessed against BB101 and CIBSE TM52 overheating metrics, ISO 7730 PMV/PPD comfort indices, and CO 2 thresholds. In London, S01 experienced recurrent overheating, peaks between 30 and 31°C and TM52 failure driven by short high-severity events with Criterion 2: 8–17 degree-hours, while CO 2 remained close to the 1000 ppm target, approximately between 1040–1050 ppm excursions. Future 2050 weather reduced annual heating from 832 to 667 kWh/m 2 ·yr and introduced cooling of 3 kWh/m 2 ·yr; 0.5% of annual thermal energy, but present in all months and peaking at 0.59 kWh/m 2 in July, yielding a 19.5% net site-energy reduction. London therefore remains heating-dominant in 2050 but with emerging peak cooling and overheating risk. In Cairo, baseline summer indoor temperatures reached 33–36°C with PPD commonly 90–100% and CO 2 peaks 1400–1500 ppm; 2050 projections extend higher than 30°C season and increase extreme events higher than 40°C, indicating intensified and prolonged cooling demand.

Research topics

  • Building Energy and Comfort Optimization
  • Indoor Air Quality and Microbial Exposure
  • Solar Energy Systems and Technologies

Sustainable Development Goals

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.1016/j.enbuild.2026.117493

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.