MARATTO

article

Assessment of Groundwater Potential of the University of Ibadan Central Mosque, Southwestern, Nigeria

2025Open accessKwara State University

Abstract

Electrical resistivity surveying using Wenner and Schlumberger electrode array was carried out for the assessment of groundwater potential at the Central Mosque, University of Ibadan. Nigeria. Three Constant Spacing Traverses (CST) and ten Vertical Electrical Sounding (VES) stations were conducted at the study area. The geoelectrical imaging from this study revealed that the lithologies consist of lateritic topsoil, sandy clay/clayey sand/clay/weathered rock and the bedrock (fractured and fresh). The fractured and weathered basement with relatively lower resistivity is inferred to be the aquiferous zone and could bear productive water for groundwater supply. The results revealed the study area to be a region of relatively high groundwater potential. It was inferred that VES 1, 2, and 8 are regions associated with high groundwater yield.

Research topics

  • Groundwater and Watershed Analysis
  • Geophysical and Geoelectrical Methods
  • Groundwater flow and contamination studies

Read the original research

This page summarises published work. The authoritative version sits with the publisher.

DOI: 10.38124/ijisrt/25may1830

Is something wrong with this record? Report it or request removal.

Discussion

Discuss this research

Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.

No discussion yet. Open the first thread.