article · PubMed
Objective: The aim of the study was to determine the intra- and inter-rater reliability of palpation technique, digital calipers, and diastometer, as well as their concurrent validity against ultrasound imaging. Methods: < 0.05. Results: It showed the palpation technique (r = 0.749-0.967 and 0.658-0.917), digital calipers (r=0.750-0.955 and 0.685-0.904), and diastometer (r=0.762-0.958 and 0.471-0.902) demonstrated good inter- and intra-rater reliability. The concurrent validity of the palpation technique, digital calipers, and diastometer against the USI was poor at all three reference points. Conclusion: Palpation technique, digital calipers, and diastometer are reliable tools but not valid substitutes to ultrasound imaging for the clinical measurement of diastasis rectus abdominis.
This page summarises published work. The authoritative version sits with the publisher.