article · Analytical Methods
Bedaquiline, a highly lipophilic molecule, is used in the treatment regimen of multi-drug resistant tuberculosis. A rare complication of pulmonary tuberculosis is tuberculous pericarditis. <i>Ex vivo</i> studies utilising animal pericardium can be used to investigate whether this drug is capable of diffusing across pericardial tissue into simulated pericardial fluid (pH 7.4) to indicate efficacy. For detection of bedaquiline in physiological fluid, a rapid, cost-effective and sensitive method is essential. The aim of this study was thus to develop and validate a simple and sensitive RP-HPLC-UV method for the detection and quantification of bedaquiline, encapsulated in a nanosystem, at pH 7.4 after permeation across excised pericardium. A HPLC Phenomenex Kinetex RPC18 column (150 × 4.6 mm, 5 μm) was utilized for analysis. The mobile phase consisted of 95 : 5 v/v (A : B), where (A) methanol : acetonitrile (85 : 15 v/v) : (B) triethylamine (1% v/v) : 0.15 mM KH<sub>2</sub>PO<sub>4</sub> buffer (pH 7.4). Running conditions included the following: injection volume 20 μl, flow rate 1.0 ml min<sup>-1</sup>, detection wavelength 275 nm, 25 °C and running time of 5 min. Bedaquiline eluted as a single symmetrical peak at a retention time of 4.17 min. The method was found to be linear within the range of 1-50 μg ml<sup>-1</sup> (<i>R</i><sup>2</sup> = 1). The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.05 μg ml<sup>-1</sup> and 0.15 μg ml<sup>-1</sup>, respectively (signal-to-noise ratio method). All validation parameters were found to be within acceptable limits (RSD < 2%). The method was fast, reliable, accurate, reproducible, and transient for the detection of bedaquiline in simulated physiological fluid (pH 7.4). This method can thus be applied to easily detect bedaquiline in body fluids (pH 7.4) <i>i.e.</i> blood and pericardial fluid without the accuracy being impacted by ionisation factors of the molecule.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1039/d4ay01143k
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.