article · Journal of Materials Research and Technology
This study investigates the influence of Zirconium (Zr) content, hot forging, and aging treatments on the microstructure, mechanical properties, magnetic response, and biological performance of Ti-14Mn-xZr (x = 0, 3, and 6 wt.%) alloys. Forging at 900 °C with ∼45% reduction followed by water quenching induced slip-dominated plastic deformation, confirmed by EBSD analysis showing deformation bands, substructures, and dislocation accumulation.EBSD analysis revealed significant dislocation accumulation and stored energy, with weighted average geometrically necessary dislocation (GND) densities of approximately 2.71 × 10 14 m −2 in Ti-14Mn-0Zr alloy and 2.45× 10 14 m −2 in Ti-14Mn-6Zr alloy. The EBSD images show several features related to the deformation bands and can be related to dynamic recrystallization, intersecting, and branching. The annealed Ti–14Mn–6Zr alloy exhibited the lowest Young’s modulus of 106.2 GPa due to high β-phase stability and a single-phase structure. Forging followed by ageing at 700 °C improved tribological performance, yielding the lowest wear rate (3.61 μm/km/N) and coefficient of friction (0.43), with worn surfaces displaying characteristic features such as parallel grooves, debris accumulation, and wear craters. Biological testing showed that the previously mentioned alloy also exhibited the highest cell viability, attributed to its enhanced hydrophilicity and surface chemical stability. These findings suggest that the aged Ti–14Mn–6Zr alloy offers a favourable combination of mechanical integrity, wear resistance, and biocompatibility for long-term biomedical applications. • A novel series of cost-effective β-type Ti–14Mn–(x)Zr alloys was developed for long-term biomedical implants. • Zr addition enhanced β-phase stability, refined microstructure, and reduced elastic modulus. • Forging and ageing treatments tailored mechanical properties, wear resistance, and surface wettability. • Ti–14Mn–6Zr alloy showed optimal performance, combining biocompatibility, low modulus, and high wear resistance.
This page summarises published work. The authoritative version sits with the publisher.
DOI: 10.1016/j.jmrt.2025.06.224
Is something wrong with this record? Report it or request removal.
Discussion
Have you built on this work, tried to replicate it, or seen it applied in practice? Share what you know. Verified researchers and MARATTO™ domain experts can open a discussion, and any member can reply. Contributions are reviewed before they appear.
No discussion yet. Open the first thread.
New to MARATTO™? Create a free account.